ABB Bailey INFI 90 and NETWORK 90 DCS upgrade to Emerson DeltaV
RoviSys and Emerson Process Management have developed a tightly integrated interface
between the DeltaV and Bailey INFI 90 and NETWORK 90 DCS that will promote future plant upgrades
to DeltaV. The interface is called the DeltaV Connect Bailey (DVC-BLY.)
This allows for easy and extremely user intuitive
replacement of Bailey
operator consoles that may have Y2K issues with NT based DeltaV consoles.
Features of the DVC-BLY include:
- Facilitates use of DeltaV hardware and software on future plant upgrades
- Use standard DeltaV configuration tools
- Replaces Bailey OIU, MCS, OIS and PCView operator consoles
- Interfaces to Bailey Command Series, Network 90 and Infi 90 systems
- Access all standard Bailey exception report types
- Allows general tuning of any Bailey block specification including PID constants
- System health monitoring
- General block output polling
Bailey Communication Interfaces Supported
The DVC-BLY has been designed to support many generations of Bailey communication interfaces. Migrating successful driver code and techniques implemented in another RoviSys product called N90DDE I/O Server, the DVC-BLY provides support for the following Bailey interfaces:
| BaileyDevice |
Points |
Exception Reports |
Control |
| NSPM01 |
500 |
No |
No |
| IMSPM01 |
500 |
No |
No |
| IMCPM02 |
500 |
No |
No |
| IMCPM03 |
500 |
Yes |
Yes |
| NCIC01 |
500 |
Yes |
Yes |
| NCIU01 |
500 |
Yes |
Yes |
| NCIU02 |
2,500 |
Yes |
Yes |
| NCIU03 |
10,000 |
Yes |
Yes |
| NCIU04 |
10,000 |
Yes |
Yes |
| INPCI01 |
500 |
Yes |
Yes |
| INPCI02 |
5,000 |
Yes |
Yes |
| INICI01 |
10,000 |
Yes |
Yes |
| INICI03 |
30,000 |
Yes |
Yes |
| INICI12 |
10,000 |
Yes |
Yes |
The DVC-BLY runs in the NT workstation environment and uses
standard PC COM ports to gain access to the above mentioned Bailey devices.
Redundancy can be utilized if multiple Bailey devices are available. DVC-BLY
does not require any configuration change to the Bailey system.
System Topology
The following diagram gives an overview of the DeltaV replacement console
topology.
Replacement costs are lower than purchasing new Y2K compliant Bailey console
hardware and software. Additional savings can be realized when replacing
Bailey 5000 tag OIU, MCS or OIS by re-using the CIU already built into
these console types.
RoviSys Legacy Integration Services
RoviSys is a full service systems integration company so we can be of
assistance in a Bailey console replacement project. Using in-house tools
and methodologies we can cost effectively translate the Bailey console
tag database into the necessary DVC-BLY configuration. Having both Bailey
and Emerson Process Management expertise, generation of new or duplication of existing
operator graphics is easily accomplished. RoviSys has also developed a
set of DeltaV console faceplates that take full advantage of the features
of the DVC-BLY blocks. Generation of the various operator graphics include
linkage to these faceplates for pop-up control.
Bailey to DeltaV Upgrade System Configuration
The DVC-BLY executes on a NT Workstation running as a DeltaV Application
Station and responds as a DeltaV controller. It executes DeltaV function
blocks which aids in promoting and enforcing DeltaV concepts and methodologies.
Standard DeltaV configuration utilizing Process Explorer and Control Studio
are used to setup the DVC-BLY and monitor its operation. Likewise, the
standard DeltaV Graphics Studio is used to configure and display operator
graphics. A new set of DeltaV function blocks have been developed which
are used to configure the DVC-BLY data exchange requirements. These blocks
are designed to be extremely intuitive to Bailey users and provide a one
for one association to existing Bailey exception reported function blocks.
In many instances additional features have been added to the DVC-BLY blocks
to augment deficiencies with the corresponding Bailey block. One example
is in the area of alarming. The standard Bailey analog block provides
for single level alarms. The corresponding DVC-BLY block enhances the
Bailey analog block data with two level alarming that is still determined
from the alarm levels set within the Bailey configuration. Features such
as this extend the basic Bailey data to match methodologies associated
with DeltaV without requiring any changes to the existing Bailey setup.
The DVC-BLY supports the following Bailey block associations:
| DVC-BLY Block |
Bailey Block |
| AIL |
Analog Output / Loop
AOL (F.C.s 30, 70, 158) |
| AOL |
Analog Input / Loop
AIL (F.C.s 26, 121) |
| BLK |
Any block specification reading and
tuning |
| DANG |
Data Acquisition Analog
DAANG (F.C. 177) |
| DD |
Device Driver
DD (F.C. 123) |
| DIL |
Digital Output / Loop
DOL (F.C. 45) |
| DOL |
Digital Input / Loop
DIL (F.C.s 42, 122) |
| IDB |
Interface Definition And Operational
Statistics |
| STAT |
Any Bailey Module |
| MSDD |
Multi-State Device Driver
MSDD (F.C. 129) |
| POUT |
Any block output |
| RCM |
Remote Control Memory
RCM (F.C. 62) |
| RMC |
Remote Motor Control
RMC (F.C. 136) |
| RMSC |
Remote Manual Set Constant
RMSC (F.C. 68) |
| STN |
Station (PID Control loop)
STN (F.C.s 21, 22, 23, 80) |
| TXT |
Text (F.C. 156) |