Legacy control system extension, migration and replacement experience

RoviSys has extensive experience in ABB Bailey legacy distributed control systems. A number of RoviSys employees were previously employed at Bailey Controls, some directly involved in the design and development of flagship legacy distributed controls, consoles and software tools. Others served as system engineers and have extensive experience in the implementation of Network 90 and Infi 90 systems.

RoviSys also has extensive experience in the replacement of the legacy distributed control system with a number of contemporary solutions. In addition to those listed here, previous projects include migrations from legacy systems to PLC5, L&N Max1 to PLC5, CRISP to PLC5, Bailey Infi90 to Emerson DeltaV, single loop controllers to PLC5 and pneumatic controls to distributed control system and PLC.

As an independent company, we are technology neutral: We recommend the solution that works best for you, not for us or any vendor. These solutions are open, documented and supportable. Whatever your legacy system extension or migration goal, if you want a conversions partner who has deep experienced in legacy and modern controls, is committed to providing open and supportable solutions and is independent and resourceful, consider RoviSys.

Legacy control system sample case histories

Infi90 console migration to modern HMI
Application

Midwestern steel maker

Legacy controls

Bailey Infi90 redundant distributed control system

New controls

Redundant Rockwell RSView SE servers
Nine RSViewSE clients on Ethernet plus 10 thin clients for reports

Implementation

Phased migration using RoviSys OPC 90 Server interface to existing Infi90 distributed control system with redundant Plant Loop
Added process calculations in RSView SE

New capability

Client able to support additional screens and tags (limited legacy ability)

 

Infi90 with Conductor NT complete replacement
Application

Powerhouse controls for Midwestern steel maker running four fuels on each of three boilers

Legacy controls

Bailey Infi90 distributed control system and consoles

New controls

Complete replacement with Rockwell ControlLogix and RSView SE HMI

Implementation

Function block programming replaced Bailey N90 configuration plus ladder enhancement
RoviSys-engineered conversion cables retained field wiring and terminations
Cable and cutover plan allowed reversal back to N90 for client fallback contingency plan
Installation began three weeks after receipt of order
One week cutover included demolition, install, startup and operational tuning
Steam maintained at all times during cutovers, only one boiler offline

New capability

Fast control reaction, avoiding past trouble during wide load swing

 

PROVOX migration to DeltaV
Application

$2 million migration for life sciences plant

Legacy controls

4,000 I/O-point Fisher PROVOX system

New controls

Emerson DeltaV distributed control system

Implementation

Multi-phased approach to minimize production downtime
P&ID walk-downs and updates
Complete GAMP life cycle documentation
Quality and project plans
Functional  and design specifications
FAT and SAT test plans
IQ and OQ documentation
System simulation using MIMIC
End of run batch reporting
Commissioning and validation execution and documentation

New capability

Project in progress

 

Honeywell TDC logic and HMI extension
Application

Hazardous waste incineration

Legacy controls

Honeywell TDC3000 distributed control system

New controls

Added Rockwell ControlLogix and RSView SE

Implementation

ProcessLinx between RoviSys OPC 90 Server and Honeywell OPC Servers
Existing Universal Stations display and control CLX loops

New capability

New RSView screens motivated operations to ask for expansion of RSView
Specification and design for complete migration is underway

 

Modcell to ControlLogix
Application

Epoxy reactor control system

Legacy controls

Modcell controllers and dedicated HMI

New controls

Rockwell ControlLogix and RSView SE PC HMI

Implementation

Three-day cutover on holiday weekend

New capability

 

Rosemont to ControlLogix
Application

Multi-tank and -mixer blending operation

Legacy controls

Rosemont RS3

New controls

Rockwell ControlLogix

Implementation

Rip and replace in one week from demolition to full production

New capability

Now run in full auto mode
Recipe-based automatic blending in CLX
Cycle time and accuracy improved significantly

 
PROVOX to ControlLogix
Application

Resin reactor and ancillary equipment

Legacy controls

PROVOX with CHiP interface to subsystems

New controls

Redundant Rockwell ControlLogix with OPC and serial interfaces

Implementation

Cutover in less than one week, including demolition and installation

New capability

Batch custom recipe builder to meet customer requirements
PROVOX for two other reactors tied to CLX for common utilities